Free for life: Get a Quote and Book Online buttons for your website. Create my widgets →Need a website? $25/mo or $500 once →
ReportWalk

Health & Safety

DSEAR Risk Assessment

A DSEAR risk assessment for UK premises that store or use flammable liquids, gases, combustible dusts or other dangerous substances: each substance with its flashpoint, limits, quantity and where it is kept, whether it can be removed or swapped, the activities that could release it and how, the hazardous area zones recorded as classified (0, 1, 2, 20, 21, 22), every kind of ignition source and how well it is controlled, equipment checked against its zone, controls and mitigation, emergency arrangements, information and training, the risk that remains, actions with owners and dates, a review date and signatures.

Free — no account, no trial, no card.

Fill this in and download the finished PDF. Your answers stay on this device as you type. We ask for an email address once, at the download.

This form deals with fire and explosion. For the harm a substance does to people who breathe it or get it on their skin — the COSHH side of the same product — use: Chemical exposure assessment

0 of 69 answered0%
1

Premises and Assessment

Which premises or plant, who is assessing, and why now.

Tell me what you seeSign in to talk instead of typing.

Include contractors, cleaners, delivery drivers and visitors, not only your own staff.

0/6 · they go into your PDF and stay on this computer

2

Dangerous Substances

Every substance here that could burn, explode or feed a fire, with the properties that decide the risk.

Tell me what you seeSign in to talk instead of typing.
Substances on site*

One entry per product or dust. Take the figures from section 9 of the safety data sheet where there is one.

Nothing added yet.

Removing or swapping comes first under DSEAR, before any control. A water-based paint, a higher-flashpoint cleaner or a smaller container all count.

0/6 · they go into your PDF and stay on this computer

3

Activities and Release Sources

Each job or piece of plant that could let a substance escape, rated as things stand.

Tell me what you seeSign in to talk instead of typing.
Activities*

Nothing added yet.

4

Hazardous Area Zoning

Where an explosive atmosphere could form, and the zone each place has been given.

Tell me what you seeSign in to talk instead of typing.

If No, the zoning and equipment questions fold away, and you record why zoning is not needed.

5

Ignition Sources

Everything that could light a release, and how well it is kept away. "Not controlled" is a safety finding.

Tell me what you seeSign in to talk instead of typing.

Controlled means done under a permit, with flammables removed or covered and a fire watch.

Controlled means a ban that is signed and actually kept, with a smoking area well away.

Anything not built for the zone it sits in counts here.

Look for earthing clips used during transfers, conductive containers and antistatic footwear where needed.

0/6 · they go into your PDF and stay on this computer

6

Equipment in Zoned Areas

Each item of electrical or mechanical equipment in a zone, checked against the zone it sits in.

Tell me what you seeSign in to talk instead of typing.

No zones recorded (see Hazardous Area Zoning), so there is no equipment to check against a zone.

7

Control and Mitigation

What keeps a release small, stops it lighting, and limits the damage if it does.

Tell me what you seeSign in to talk instead of typing.

0/6 · they go into your PDF and stay on this computer

8

Accidents, Incidents and Emergencies

What happens if there is a spill, a release, a fire or an explosion.

Tell me what you seeSign in to talk instead of typing.

Answer N/A where there is nothing to isolate.

A plan at the entrance or a premises information box both work.

9

Information and Training

Whether the people who handle these substances, and those nearby, know the risks and the precautions.

Tell me what you seeSign in to talk instead of typing.
10

Overall Risk, Actions and Sign-Off

Where things stand, what will be done, and when this is reviewed.

Tell me what you seeSign in to talk instead of typing.

For area classification, equipment selection or explosion protection on dust plant.

Actions

Nothing added yet.

0/10 · they go into your PDF and stay on this computer

Sign above — Assessor
Sign above — Manager

Free, no account needed. Your answers never leave this browser.

A DSEAR risk assessment looks at the substances on a site that can burn or explode — solvents, paints, fuels, LPG, flammable gases, fine dusts from wood, flour, sugar or metal — and asks three questions: where could they get out, could the escape form a cloud that would ignite, and what is stopping that from happening. This template walks through the substances, the activities that release them, the hazardous zones, the ignition sources, the equipment in those zones, and the controls and emergency plans, so that each gap ends up as an action with an owner. Fill it in here and download a PDF without an account, or speak while you walk, and the document writes itself.

What DSEAR asks of an employer

The Dangerous Substances and Explosive Atmospheres Regulations 2002 apply across Great Britain wherever work involves a substance that could cause a fire, explosion or similar energetic event. Northern Ireland has its own equivalent regulations. The employer has to assess the risk, remove it or reduce it as far as reasonably practicable, classify any places where an explosive atmosphere could form, provide arrangements for accidents and emergencies, and tell and train the people involved. With five or more employees, the significant findings must be written down.

The Regulations reach far beyond chemical plants. A joinery workshop with a dust extractor, a garage with a petrol can and a battery charger, a print room with solvent wipes, a bakery with flour silos and a warehouse with LPG forklifts are all in scope.

Substances first, then how they get out

List each substance with the properties that matter for fire: its flashpoint, its flammable range, the temperature at which it ignites on its own, and for dusts how easily a cloud ignites. The safety data sheet has most of this. Then record how much is used and stored, and where.

Next come the activities that could let it out: decanting from drums, spraying, brushing, charging batteries, emptying a dust collector, purging a vessel, refuelling. For each, note whether a release is continuous, expected in normal running, or would only follow a failure, and how good the ventilation is. Those two answers drive the zoning.

Zones are recorded here, not calculated

Where an explosive atmosphere could form in a quantity that needs special precautions, the area is classified into zones: 0, 1 and 2 for gas, vapour and mist, and 20, 21 and 22 for dust clouds, from the most to the least likely. The form records the zone and its extent as the area classification drawing or the assessor gives them. It does not work zones out for you.

Small, simple sites can often show that no zoning is needed, and the form asks you to say why. Larger or more complex sites — process plant, bulk tanks, large dust systems, anything with a Zone 0 or 20 — need someone competent in explosion protection to do the classification and to check the whole arrangement before a zoned area is first used.

Ignition sources and equipment

An explosive atmosphere does no harm until something lights it. The form goes through each kind of source in turn — naked flames, hot work, smoking, ordinary electrical kit, static, hot surfaces, sparks from tools or impact, vehicles, phones — and asks how well each is controlled where the substance could be.

Equipment used in a zone must be built for that zone, and its marking shows what it is fit for. A category 1 product is needed in Zone 0 or 20, category 2 or better in Zone 1 or 21, and category 3 or better in Zone 2 or 22. Each item is checked against the zone it sits in, and anything unsuitable becomes a safety finding.

Common questions

Who needs a DSEAR risk assessment?

Any employer or self-employed person in Great Britain whose work involves a substance that could burn or explode — flammable liquids and gases, combustible dusts, oxidisers and the like — whatever the quantity. Where only tiny amounts are used, the assessment can be short and say so.

What is the difference between DSEAR and COSHH?

COSHH covers harm to health from breathing, swallowing or touching a substance. DSEAR covers harm from fire, explosion and similar events. Many products, such as solvents, need both, and the two assessments can sit side by side.

What do Zones 0, 1 and 2 mean?

They describe how likely an explosive gas or vapour atmosphere is. Zone 0 is present continuously or for long periods, Zone 1 is likely now and then during normal operation, and Zone 2 is not expected in normal operation and short-lived if it happens. Zones 20, 21 and 22 mean the same for clouds of combustible dust.

Do I always need hazardous area zoning?

No. Zoning is needed where an explosive atmosphere could form in such quantities that special precautions are required. Many small users of flammable products can show that the quantities and ventilation mean it cannot. Record that reasoning in the assessment.

Who can carry out a DSEAR assessment?

A competent person, who understands the substances, the process and the site. A small workshop owner can often assess a simple situation with guidance; area classification and equipment selection on a complex site need a specialist in explosion protection.

Does completing this template make us compliant with DSEAR?

No form can do that on its own. It records what was assessed, what was found and what will be done. Whether the arrangements are adequate is judged against the Regulations and the approved code of practice by someone competent to do so.