A fire drill checklist and report for one practice evacuation: how the alarm was raised and who was told, whether it was heard everywhere, exits and escape routes, how people responded, assisted evacuation, roll call by area, evacuation times against your target, a debrief, corrective actions and sign-off.

Free — no account, no trial, no card.

Fill this in and download the finished PDF. Your answers stay on this device as you type. We ask for an email address once, at the download.

A drill shows whether people can find the way out. Whether the lights along that way stay on when the power fails is a separate monthly test: Emergency lighting and exit sign inspection

0 of 73 answered0%
1

Drill Details

Where, when, who ran it, and what kind of drill it was.

Tell me what you seeSign in to talk instead of typing.

e.g. Ana — north stairwell; Raj — assembly point B.

Blocking one exit on purpose shows whether people know their second way out.

2

Before the Alarm

The people who must know a drill is coming, told before it starts.

Tell me what you seeSign in to talk instead of typing.

Note who you spoke to and the reference they gave.

3

Alarm and Warning

Whether the warning reached everybody, and the building reacted as designed.

Tell me what you seeSign in to talk instead of typing.

Observers in far corners are the only reliable way to know.

0/4 · they go into your PDF and stay on this computer

4

Exits and Escape Routes

The way out, as people actually used it.

Tell me what you seeSign in to talk instead of typing.

Unless your plan provides evacuation lifts, the right answer is No.

0/6 · they go into your PDF and stay on this computer

5

How People Responded

Behaviour on the way out, watched rather than assumed.

Tell me what you seeSign in to talk instead of typing.
6

Assisted Evacuation

Only if someone needed help to get out. Listed by role or initials.

Tell me what you seeSign in to talk instead of typing.

Answer No and this whole section folds away. It is not counted in the score.

7

Assembly Point and Roll Call

Everyone counted, and the times that matter.

Tell me what you seeSign in to talk instead of typing.
Roll call by area or warden

Nothing added yet.

Use the visitor book or sign-in system, not memory.

min
min

0/3 · they go into your PDF and stay on this computer

8

All-Clear and Debrief

Putting the building back, and what the drill taught you.

Tell me what you seeSign in to talk instead of typing.
9

Actions and Sign-Off

Who fixes what, by when, and who signed for the drill.

Tell me what you seeSign in to talk instead of typing.
Corrective actions

Nothing added yet.

By signing, the coordinator confirms the drill took place as recorded and that the times and results above are what was observed.

Sign above — Coordinator
Sign above — Manager

Free, no account needed. Your answers never leave this browser.

A fire drill checklist is the record of one practice evacuation: how the alarm reached people, whether the escape routes worked, how people behaved on the way out, whether everyone was accounted for and how long it all took. This form walks through a drill in the order it happens and ends with a list of what to fix before the next one. Fill it in here and download the report as a PDF, or speak while you walk, and the document writes itself.

What a drill is for

A drill is a test of the plan, not of the people. It finds the alarm sounder nobody can hear in the back store, the exit door that needs a key, the stairwell full of archive boxes, the warden who has left the company, the assembly point that sits where the fire trucks need to park. Every one of those is cheap to fix on a Tuesday morning and very expensive to discover during a real fire.

So the most useful part of the record is not the score. It is the list of problems at the end, each with a name and a date against it, and the check at the next drill that they were dealt with.

Time it, and know what you are aiming for

Write down three times: when the alarm sounded, when the last person was out of the building, and when roll call was complete. The gap between the first two is your evacuation time; the gap to the third is how long the fire department would wait to hear whether anyone is missing.

A target time belongs in your emergency plan, set for your building by whoever designed or assessed it — there is no single correct number for every building. Record it here so each drill is measured against the same yardstick, and the trend over a year tells you whether training is working.

Announced, unannounced and partial drills

An announced drill is a fair way to start in a new building or with new staff; it tests the routes without testing reactions. An unannounced drill tests what people actually do when the alarm goes. A partial drill — one floor, or one shift — is often the only practical option in a hospital, a care home or a factory that cannot stop. The form records which kind it was, so a quick, calm drill that everybody knew about is not mistaken for proof that the building is ready.

Tell the alarm monitoring company before you set the alarm off, or they will dispatch the fire department. Many departments are glad to be told in advance, and some will send a crew to watch.

People who need help to get out

Anyone who cannot use the stairs unaided, cannot hear the alarm or does not know the building needs a plan made in advance, not improvised on the day. The assisted evacuation section opens only if someone needed help, and lists them by role or initials rather than full name. Whether each person reached safety, and how long it took, is the part of the drill most worth practising and most often skipped.

Common questions

How often should we hold a fire drill?

It depends on the occupancy and where you are. In the US the fire code and NFPA 101 set frequencies by occupancy type — schools much more often than offices, for example — and your local fire marshal may set more. In the UK, guidance for most workplaces is at least once a year, more often for higher-risk premises or shift work. Check what applies to your building and record it in your plan.

Who should run the drill and fill in the checklist?

Whoever is responsible for the emergency plan, or a safety coordinator they appoint. It works best with an observer or two at points the coordinator cannot see — a stairwell, the far exit, the assembly point — who report back for the debrief.

Should we tell people a drill is happening?

Tell the monitoring company, security and anyone whose work cannot safely stop. Whether to tell everyone else depends on what you want to test. The form records which kind of drill it was so the results can be read fairly.

What counts as a failed drill?

Anything that would have put someone at risk in a real fire: an area where the alarm could not be heard, an exit that would not open, someone unaccounted for at roll call, someone going back inside before the all-clear. Each of those shows up as a failed check in the report and should become an action with an owner.

How long should we keep fire drill records?

Keep them for at least as long as your local code requires, and in any case until the next fire risk assessment or inspection has seen them. An enforcing officer or insurer will usually ask for the last few drills, the times, and what was done about the problems found.